PERANCANGAN DESAIN RUANGAN DATA CENTER MENGGUNAKAN STANDAR TIA-942

(STUDI KASUS : UPT SIMJAR STMIK STIKOM INDONESIA)

Authors

  • I Dewa Putu Gede Wiyata Putra STMIK STIKOM Indonesia
  • Made Dona Wahyu Aristana STMIK STIKOM Indonesia

DOI:

https://doi.org/10.31598/jurnalresistor.v2i1.370

Keywords:

Datacenter, TIA, Tier

Abstract

The rapid development of information systems has an impact on increasing data storage and processing needs. Data center is a facility that consists of computer networks and storage used by other businesses or organizations to organize, process, store and disseminate large amounts of data. Data center UPT SIMJAR STIKI Indonesia has a small size of computer room, without backup power supply, space construction and security systems that are not ideal. As a result of these conditions, the process of service activities of UPT SIMJAR was disrupted. To overcome this problem, it is necessary to standardize the data center so that good data center criteria are formed, namely availability, scalability / flexibility and security. The method carried out in this design is to analyze the requirements listed in the TIA-942 standard, and proceed with the design in accordance with the required criteria. The purpose of this research is to produce a data center design that complies with the TIA-942 standard for UPT SIMJAR STIKI Indonesia.

Downloads

Download data is not yet available.

References

S. Sauri and M. T. Kurniawan, “DESAIN DAN ANALISIS GREEN DATA CENTER DI FAKULTAS REKAYASA INDUSTRI UNIVERSITAS TELKOM MENGGUNAKAN STANDAR TIA-942 HEAT DISSIPATION,†e-Proceeding Eng., vol. 2, no. 2, p. 15, 2015.

M. Uddin and A. A. Rahman, “Server Consolidation: An Approach to Make Data Centers Energy Efficient & Green,†Int. J. Sci. Eng. Res., vol. 1, no. 1, p. 7, 2010.

D. E. Yulianti and B. N. Nanda, “Best Practice Perancangan Fasilitas Data Center DAT A CENTER,†Bandung Inst. Teknol. Bandung, 2008.

I. Caesar, R. R. Saedudin, and U. Y. K. S. Hediyanto, “Analisis Dan Perancangan Power Management Data Center Berdasarkan Tiering Level Di Pemerintahan Kabupaten Bandung Menggunakan Standar Tia-942 Dengan Metode PPDIOO Life-Cycle Approach,†J. Rekayasa Sist. Ind., vol. 3, no. 4, 2016.

F. F. Asali and I. Afrianto, “Rekomendasi Data Center Menggunakan Pendekatan Standarisasi TIA-942 di Puslitbang XYZ,†J. CoreIT, vol. 3, no. 1, p. 10, 2017.

Telecommunication Industry Assosiation, “Telecommunication Industry Assosiation.†TIA-942 Standard, 2012.

D. F. Channon and T. Sammut-Bonnici, “Gap Analysis,†in Wiley Encyclopedia of Management, C. L. Cooper, Ed. Chichester, UK: John Wiley & Sons, Ltd, 2015, pp. 1–2.

N. Rasmussen, “Raised Floors vs Hard Floors for Data Center Applications,†p. 14.

P. Lin and V. Avelar, “How Row-based Data Center Cooling Works,†p. 10.

K. Dunlap and N. Rasmussen, “The Advantages of Row and Rack- Oriented Cooling Architectures for Data Centers,†p. 21.

ANSI/TIA, Telecommunications Infrastructure Standard for Data Centers, no. August. 2012.